ALMA – Arnaud Legoux Moving Average

ALMA – Arnaud Legoux Moving Average

The ALMA moving average uses curve of the Normal (Gauss) distribution which can be placed by Offset parameter from 0 to 1. This parameter allows regulating the smoothness and high sensitivity of the Moving Average. Sigma is another parameter that is responsible for the shape of the curve coefficients. This moving average reduce lag of the informations but still being smooth to reduce noises.

This method of price average calculation could be used for any others technical indicators that used moving average for their own calculation (RSI, MACD, Stochastic, etc.).

From the Author: (Arnaud Legoux & Dimitris Kouzis-Loukas)

It removes small price fluctuations and enhances the trend by applying a moving average twice, one from left to right and one from right to left. At the end of this process the phase shift (price lag) commonly associated with moving averages is significantly reduced. Zero-phase digital filtering reduces noise in the signal. Conventional filtering reduces noise in the signal, but add delay.

The ALMA can give some excellent results if you take the time to tweak the parameters (don’t need to explain this part, it will be easy for you to find the right setting in less than hour)..

 

Share this

Risk disclosure:

No information on this site is investment advice or a solicitation to buy or sell any financial instrument. Past performance is not indicative of future results. Trading may expose you to risk of loss greater than your deposits and is only suitable for experienced investors who have sufficient financial means to bear such risk.

ProRealTime ITF files and other attachments : How to import ITF files into ProRealTime platform?

PRC is also on YouTube, subscribe to our channel for exclusive content and tutorials

  1. supertiti • 06/06/2016 #

    Bonjour Nicolas
    J’ai mis la moyenne ALMA sur des prix et j’ai ajouté une autre moyenne simple par exemple p= 11 , quand je bouge les paramètres de ALMA l’autre moyenne bouge aussi !
    Est ce normal ? et si oui pourquoi ?
    merci, bonne journée
     

    • Nicolas • 06/06/2016 #

      Bonjour titi, je pense que tu dois faire erreur, ça n’est possible 🙂

  2. supertiti • 06/06/2016 #

    Sorry ! erreur de débutant ! le bug venait de ” appliqué à ” qui s’adressait à ALMA en place de customclose …

  3. ACPRT • 06/06/2016 #

    Bonjour . j’ai un problème lorsque la variable Windows prend la valeur très grande, par exemple à partir de 300, j’ai seulement un petit bout de la courbe. Est-ce que quelqu’un aurait une petite idée ?
    Je vous remercie par avance de votre réponse.

    • Nicolas • 06/06/2016 #

      Augmenter la quantité d’unités affichées à l’écran

  4. SB-FO • 06/06/2016 #

    Nicolas, how does one convert this into an indicator?

    • Nicolas • 06/06/2016 #

      This is already an indicator. Download the itf file, import it into ProRealTime an apply it on the price chart.

  5. Bruno Carnazzi • 06/06/2016 #

    Moyenne mobile intéressante, dommage qu’elle soit si gourmande en puissance de calcul. Les valeurs supérieures à 200 (ou pire 500) ont tendance à peser sur PRT. C’est un peu mieux en v11 mais ça reste un point noir (freeze de quelques secondes pour recalcul de la MM)

  6. PeP2016 • 06/06/2016 #

    Hi, simple and nice idea. One question though: I read
    it removes small price fluctuations and enhances the trend by applying a moving average twice, one from left to right and one from right to left.
    but can’t see this double “run”. Can you please explain this point? thanks.

avatar
Register or

Likes

avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar avatar
Related users ' posts
r.angel It seems that the formula needs a SQRT (that is Vyangzhang = SQRT(...))
RickTrader I think to have annualized view of this historical volatility you will need : Vyangzhang =...
Nicolas
10 years ago
Miko31 Very good ! Many thanks
Nicolas
10 years ago
Nicolas
10 years ago
Vinks_o_7 great, thanks Nicolas !
Vinks_o_7 argh...still nothing even with 10 000 bars on daily or hourly basis...
Vinks_o_7 ok now : had to refresh the indicator.
211 Really nice indicator Nicolas! Well done!
supertiti Bonjour Nicolas comme j'avais l'impression qu'il en manque un bout j'ai fais ça : Peux...
Nicolas Merci supertiti ! C'est juste, encore un ptit bug quelquepart ! :|
Nicolas
10 years ago
Sniper T3-CCI
Sniper T3-CCI
0
Indicators
Nicolas
10 years ago
Nicolas
10 years ago
Denis Bonjour Nicolas, j'ai une question à propos de ce code, il faut que je la pose en anglais ca...
Nicolas En français pas de problème
robertogozzi Vous ne pouvez pas, car ProBuilder ne prend actuellement pas en charge MTF (Multiple Time Fr...
jeanguy Merci pour ce travail En quoi cette MM est elle différente d’une MM courte ?
Bern latest version pro real time not accepting code, same with Ehler's MAMA indicator. any idea...
Lotech123 This Indicator is very useful if the Risk number is altered to suit the time frame, volume o...
Bern error displaying, code must end with RETURN. Any idea hot to fix it?
j102491 how are you applying it to asc trend
Nicolas
10 years ago
Acceleration Bands
Acceleration Bands
0
Indicators
cepamoi Unfortunately, this still does not work: ONCE haOpen = medianprice haOpen = ((Open[1]+High...
Nicolas Force calculation to wait 1 bar of history already loaded: ONCE haOpen = medianprice if b...
cepamoi Now it works. Thanks a lot Nicolas! Here is the full code: // variables : // period ...
Nicolas
10 years ago
JosephFelix Hi Nicolas. Thank you for your excellent work. I am new to the platform. I have just import...
Alai-n Tout fonctionne bien dans cet indicateur? Quelle est la variable "Seuil" dans le code? Pourq...
Nicolas Oui il fonctionne, il faut que l'instrument analysé possède des Volumes. La variable "seuil"...

Top