Three lower (and higher) Closes John Carter’s Scalping Indicator

v10.3
Three lower (and higher) Closes John Carter’s Scalping Indicator

Hi to all,

I’m reading chapter 14 of John Carter’s “Mastering The Trade” (2nd edition), which describes a setup to open position after trend has changed and a three candle pattern has been formed.

For example, to go short following new trend when old trend was bullish, Carter says that you have to check for three consecutive lower closes, that means that reversal has been confirmed and trader has to go short at market.

At the same way, reversed rules are valid for bullish signal: after a reversal from a bearish to bullish, you have to check for three consecutive higher closes.

Carter adds a filter to avoid “Flags” (consolidation situations): in case of three lower closes, the close of the last two candles must be lower than the low of the first candle of the pattern; at the same way for bullish, the close of the last two candles must be higher than the high of the first candle of the pattern.

Using that rules, I tried to write an indicator that paint green (for bullish) an red (for bearish) arrows on the chart.

Note that when the first arrow is painted after a market reversal, You are on the market so You must ignore the following candles having the same color.

The original John Carter’s indicator for Trade Station put the signal to the first candle of the pattern. My indicator put the arrow to the third candle of the pattern, that is the entry candle.

Here’s the code:

 

Share this

Risk disclosure:

No information on this site is investment advice or a solicitation to buy or sell any financial instrument. Past performance is not indicative of future results. Trading may expose you to risk of loss greater than your deposits and is only suitable for experienced investors who have sufficient financial means to bear such risk.

ProRealTime ITF files and other attachments : How to import ITF files into ProRealTime platform?

PRC is also on YouTube, subscribe to our channel for exclusive content and tutorials

  1. zilliq • 03/06/2017 #

    Hi Francesco,
    Thanks for your code,
    There is a little error. You need to add the notion of reversal (-1/+1). Because without this you will have too much signal as you see on your picture
    Carter advice to take position to the third and exit wit hthe other signal
    Sadly, I do an algo last week and the results are not very fantastic…May be the things change since his book
    Regards
    Zilliq
     
    https://www.zilliqtradingresearch.fr/
    Coding is not a crime 😉
     

    • mikael • 03/06/2017 #

      Hi Zilliq!
      I don`t understand were to put the notion of  reversal (-1/+1). Can you please exlain or show in the code?
       
      Regards Mikael

  2. Sofitech • 03/06/2017 #

    Hello. How can we modify the code to have an alert on each arrow buy and sell…? RETURN…..So we can test it with an alert in Prorealtime ?

avatar
Register or

Likes

avatar avatar avatar avatar avatar avatar
Related users ' posts
lolo
10 years ago
KST
KST
1
Indicators
Alai-n Bonjour. Que cela soit cette formulation du KST ou celle par défaut de la plateforme PRT, au...
lolo
10 years ago
SafeZone Stop - Elder
SafeZone Stop – Elder
0
Indicators
lolo
10 years ago
Hull moving average
Hull moving average
8
Indicators
Hynesjp Hi Nicolas, I followed your suggestion to be able to change the colour but I cannot get the ...
Nicolas Remove the COLOURED instruction from the last line of the code.
Jozo Hi Guys, could you help? When I attach this Hull MA it goes to subwindow! It should attach o...
lolo
10 years ago
Swing Hilo
Swing Hilo
0
Indicators
lolo
10 years ago
Projection Oscillator
Projection Oscillator
0
Indicators
lolo
10 years ago
Projection Bands
Projection Bands
0
Indicators
lolo
10 years ago
Hammer
Hammer
0
Indicators
lolo
10 years ago
Thermometer
Thermometer
0
Indicators
lolo
10 years ago
%B Bollinger
%B Bollinger
7
Indicators
Laurent Thanks a lot
oraclus Bonjour le %bollinger est protégé sur Prorealtime. Le code ci-dessus est paramétré par défau...
Nicolas Le code dans ce post répond à cette demande d'adaptation de la période du %Bollinger: https:...
lolo
10 years ago
Trend Force
Trend Force
3
Indicators
Petrus Hi Lolo.   If you put on the graph only the difference between both values, the resul...
swapping Trend Force with Background Color
swapping // --- property setting //Alpha = 40 // Transparency backgroundcolor // --- end // Dete...
lolo
10 years ago
TD REI
TD REI
0
Indicators
lolo
10 years ago
ZIGZAG TREND
ZIGZAG TREND
4
Indicators
Vonasi I'm interested in this indicator but it does not appear to work on 10.3. Could it be possibl...
Nicolas You need to change the 'amnt' variable to a percentage, so if you set it to 10 it represents...
Vonasi Thanks for your reply - I had tried that - I set the amnt to 1 on a 15 min GBPUSD chart and ...
lolo
10 years ago
Demarker
Demarker
0
Indicators
lolo
10 years ago
Schaff Trend Cycle
Schaff Trend Cycle
3
Indicators
Fabio Anthony Terrenzio what are the two orizzontal line?
ggolfet The results I get from this indicator seem different from the results obtained using the ind...
Nicolas An accurate indicator (identical to the platform one) for Schaff Trend Cycle is now also ava...
lolo
10 years ago
lolo
10 years ago
lolo
10 years ago
BuilderRVI
BuilderRVI
0
Indicators
Nicolas
10 years ago
Guibourse HI, I wonder how to change the mid line color depending on its growing or declining evolutio...
Brent38 Bonjour à tous, Post tardif, mais on débute tous un jour, et moi je découvre Prorealcode. ...
Nicolas Oui en effet, le TDI c'est un RSI lissé avec des écarts types sur sa moyenne.
Nicolas
10 years ago
Tradesun Salve, ho provato ad inserire l'indicatore nella piattaforma ma mi chiede di definire la var...
maximus78 Tradesun, se scarichi il file ITF allegato e lo importi nella piattaforma ci sono già le var...
Nicolas
10 years ago
Klinger oscillator
Klinger oscillator
4
Indicators
Nicolas Because they are external variables and not present in the code. Please download the itf fil...
fykemang Whenever I attempt to apply this to a chart, the value is 0, not sure what is wrong.
Nicolas The Klinger Oscillator needs Volume in order to be calculated. Apply it on an instrument tha...

Top